← All sessions

SESSION TRP-EXP-20261004-133024

General Experimental

Published Threshold Research Platform session recorded using Muse S Athena. EEG summaries are derived from the saved raw EEG file. Muse S Athena physiology values are derived from the published optical processing layer; HbO, HbR and oxygenation remain baseline-relative research indices.

Published

FINDINGS SUMMARY

Session Results Overview

DESCRIPTIVE SUMMARY
EEG RESPONSE

The largest EEG band increase relative to baseline was Gamma at +250.5%. The largest EEG band decrease relative to baseline was Delta at -14.0%.

AUTOMATED STATE

The highest mean automated state estimate was Focused / Active at 42.3%. Time-distortion probability peaked at 77.6%. Peak artifact risk was 100.0%.

TIME PERCEPTION

Automated time-distortion probability peaked at 77.6%. No subjective time-perception report was published for comparison.

PHYSIOLOGY

Published physiology summary: heart rate 94 BPM, HRV 104 ms RMSSD, Brain HbO +0.1%, Brain HbR +0.9%, relative oxygenation -0.7%.

SESSION OBSERVATIONS

The session contains 72 event markers (70 automatic, 2 manual/system) and 0 subject-reported observations.

This summary is generated from the published session dataset and is descriptive only. Automated state percentages are calibration-relative heuristic research scores rather than diagnoses or trained clinical classifiers. Temporal association does not establish causation, and HbO/HbR/Oxygenation remain baseline-relative optical research indices.

Delta Change -14.0% Experiment vs baseline
Theta Change -8.0% Experiment vs baseline
Alpha Change +9.4% Experiment vs baseline
Beta Change +202.4% Experiment vs baseline
Gamma Change +250.5% Experiment vs baseline

AUTOMATED ANALYSIS

Research State Estimates

CALIBRATION RELATIVE
Meditation-like 14.3% Mean · Peak 49.0% Alpha/Theta-weighted pattern
Focused / Active 42.3% Mean · Peak 87.4% Beta/Gamma-weighted activation pattern
Relaxed Alpha 16.5% Mean · Peak 46.9% Alpha-dominant low-motion pattern
Drowsy / Low-Frequency 24.8% Mean · Peak 56.4% Delta/Theta-weighted pattern
Time Distortion 16.5% Mean · Peak 77.6% Temporal-processing research probability
Artifact Risk 55.6% Mean · Peak 100.0% Motion / high-frequency screening
Interpretation boundary: These percentages are calibration-relative heuristic research scores. They are intended for within-session and repeated-session correlation. Time Distortion is not a validated population probability, and the state labels are not medical or psychological diagnoses.

STATE TREND

Published Automated State Samples

451 samples
Elapsed Meditation Focused Relaxed Drowsy Time Dist. Artifact
00:01 17.7% 20.4% 21.3% 29.2% 0.1% 64.8%
00:09 13.9% 13.1% 16.6% 35.7% 3.7% 68.0%
00:17 9.9% 22.1% 14.8% 25.9% 1.3% 68.0%
00:25 17.1% 11.4% 19.8% 38.2% 2.4% 68.0%
00:34 10.3% 21.6% 13.8% 27.4% 1.2% 68.0%
00:42 17.8% 11.2% 19.8% 38.9% 2.6% 68.0%
00:50 15.2% 14.6% 16.6% 34.9% 1.1% 68.0%
00:58 10.3% 18.7% 15.3% 27.9% 3.2% 68.0%
01:06 16.2% 12.7% 22.6% 33.2% 0.9% 68.0%
01:14 12.3% 15.1% 15.6% 32.8% 3.7% 68.0%
01:22 10.1% 19.4% 14.9% 28.0% 3.3% 68.0%
01:31 7.9% 26.9% 11.1% 24.7% 2.4% 72.5%
01:39 12.8% 13.1% 16.1% 35.1% 7.9% 68.0%
01:47 9.1% 46.3% 11.5% 21.8% 1.4% 67.9%
01:55 12.2% 12.9% 16.7% 33.9% 9.3% 68.0%
02:03 13.8% 11.9% 17.3% 35.9% 5.8% 68.0%
02:11 6.2% 69.6% 7.6% 14.3% 18.5% 78.6%
02:20 11.4% 16.1% 14.6% 32.2% 4.9% 68.0%
02:28 12.5% 14.4% 16.7% 32.5% 4.3% 68.0%
02:36 17.9% 17.0% 20.4% 32.9% 0.2% 68.0%
02:44 14.5% 13.7% 17.0% 35.1% 2.3% 68.0%
02:52 10.7% 13.2% 14.5% 33.8% 14.0% 68.0%
03:00 10.7% 14.6% 15.2% 31.6% 10.1% 68.0%
03:08 3.5% 80.7% 4.3% 7.6% 10.5% 100.0%
03:17 9.4% 16.6% 13.8% 29.7% 11.1% 68.0%
03:25 13.3% 69.5% 14.7% 22.2% 41.8% 31.1%
03:33 13.0% 25.0% 16.9% 30.4% 8.2% 42.8%
03:41 9.3% 14.6% 13.6% 31.1% 15.6% 68.0%
03:49 14.1% 12.7% 17.3% 35.3% 3.4% 68.0%
03:57 5.4% 73.2% 6.3% 11.2% 2.5% 95.8%
04:05 35.4% 11.5% 22.1% 49.1% 1.3% 68.0%
04:14 14.6% 12.9% 16.1% 37.0% 3.1% 68.0%
04:22 9.6% 22.7% 12.6% 27.4% 2.5% 68.0%
04:30 4.6% 58.3% 6.6% 14.7% 9.1% 93.2%
04:38 7.8% 49.8% 9.0% 17.6% 1.4% 81.5%
04:46 16.4% 18.1% 18.1% 34.5% 0.8% 57.4%
04:54 19.8% 13.4% 17.1% 39.8% 3.0% 68.0%
05:03 11.8% 14.4% 16.1% 32.4% 7.1% 68.0%
05:11 10.5% 86.5% 11.2% 8.1% 48.5% 32.0%
05:19 10.6% 86.5% 10.2% 8.0% 50.1% 32.0%
05:27 2.9% 81.9% 4.6% 4.5% 14.0% 100.0%
05:35 11.4% 86.1% 11.3% 9.1% 38.3% 32.0%
05:43 8.7% 87.0% 9.7% 5.2% 70.9% 32.0%
05:52 8.5% 87.2% 10.1% 4.5% 69.8% 32.0%
06:00 9.1% 87.1% 10.7% 4.9% 64.3% 32.0%
06:08 25.9% 83.3% 33.0% 12.4% 59.7% 32.0%
06:16 9.7% 86.7% 9.9% 6.3% 61.5% 32.0%
06:24 26.2% 85.8% 40.4% 9.3% 77.5% 32.0%
06:32 32.0% 84.5% 46.6% 11.0% 71.8% 32.0%
06:41 19.2% 85.1% 20.7% 12.9% 10.9% 32.0%
06:49 21.9% 84.2% 27.6% 11.9% 41.9% 32.0%
06:57 17.9% 83.8% 21.0% 12.8% 16.8% 32.0%
07:05 19.4% 63.7% 17.4% 23.4% 26.1% 18.2%
07:13 25.1% 84.6% 25.5% 11.9% 39.5% 32.0%
07:21 6.7% 56.7% 8.9% 13.8% 3.6% 86.5%
07:29 15.5% 12.8% 17.3% 36.5% 1.9% 68.0%
07:38 8.8% 19.7% 12.0% 28.9% 9.2% 68.0%

Long sessions are downsampled for browser review. The published JSON retains the full web-review state series.

TEMPORAL PROCESSING

Time-Perception Correlation

EEG + SUBJECT REPORT
Mean Deviation 55.2 / 100
Peak Deviation 86.2 / 100
Mean Alpha Peak / IAF —
Candidate Epochs 75
Peak Time-Distortion Probability 77.6%

Automated temporal-processing data were published, but no subjective time-perception report was entered for comparison.

Correlation note: TRP records the automated EEG-derived temporal measure independently from the subject's later faster/slower/expanded/compressed report. Agreement is therefore available for later repeated-session analysis without treating the automated score as a direct decoder of subjective time.

PHYSIOLOGY

Physiological Response

ATHENA OPTICAL
Heart Rate 94 BPM Optical pulse-derived
HRV 104 ms RMSSD
Brain HbO +0.1 % Baseline-relative index
Brain HbR +0.9 % Baseline-relative index
Oxygenation -0.7 % HbO − HbR relative index
Measurement note: Heart rate and HRV are derived from the Muse S Athena optical pulse waveform. Brain HbO, Brain HbR and Oxygenation are baseline-relative optical research indices and are not clinical SpO₂ or absolute hemoglobin measurements.

SESSION TREND

Published Physiology Samples

226 samples
Elapsed Heart Rate HRV Brain HbO Brain HbR Oxygenation
00:01 — — +0.0 % +0.4 % -0.3 %
00:09 91 BPM 118 ms +0.0 % +0.3 % -0.2 %
00:17 89 BPM 95 ms +0.1 % +0.2 % -0.2 %
00:26 89 BPM 117 ms +0.1 % +0.7 % -0.7 %
00:34 94 BPM 133 ms +0.1 % +0.6 % -0.5 %
00:42 94 BPM 94 ms +0.1 % +1.0 % -0.9 %
00:50 94 BPM 97 ms +0.1 % +0.6 % -0.5 %
00:58 94 BPM 98 ms +0.1 % +1.0 % -0.9 %
01:06 87 BPM 161 ms +0.1 % +1.0 % -0.9 %
01:14 89 BPM 177 ms +0.1 % +1.1 % -1.0 %
01:23 94 BPM 104 ms +0.1 % +1.1 % -1.0 %
01:31 96 BPM 107 ms +0.1 % +1.1 % -1.0 %
01:39 96 BPM 108 ms +0.1 % +0.9 % -0.8 %
01:47 96 BPM 107 ms +0.1 % +1.1 % -1.0 %
01:55 91 BPM 106 ms +0.1 % +1.4 % -1.3 %
02:03 91 BPM 124 ms +0.1 % +0.6 % -0.5 %
02:11 89 BPM 138 ms +0.1 % +1.2 % -1.1 %
02:20 94 BPM 138 ms +0.1 % +1.3 % -1.2 %
02:28 94 BPM 131 ms +0.1 % +1.1 % -0.9 %
02:36 96 BPM 122 ms +0.1 % +0.3 % -0.2 %
02:44 96 BPM 106 ms +0.1 % +1.1 % -1.0 %
02:52 95 BPM 122 ms +0.1 % +1.1 % -1.0 %
03:00 94 BPM 117 ms +0.1 % +1.1 % -1.0 %
03:08 94 BPM 110 ms +0.1 % +1.1 % -1.0 %
03:17 94 BPM 120 ms +0.1 % +1.2 % -1.1 %
03:25 91 BPM 104 ms +0.1 % +1.2 % -1.1 %
03:33 94 BPM 102 ms +0.1 % +1.3 % -1.2 %
03:41 94 BPM 75 ms +0.1 % +1.1 % -0.9 %
03:49 94 BPM 99 ms +0.1 % +0.6 % -0.5 %
03:57 91 BPM 212 ms +0.1 % +0.5 % -0.4 %
04:05 93 BPM 91 ms +0.1 % +0.8 % -0.7 %
04:14 95 BPM 206 ms +0.1 % +0.6 % -0.5 %
04:22 98 BPM 124 ms +0.1 % +0.8 % -0.7 %
04:30 96 BPM 94 ms +0.1 % +0.7 % -0.6 %
04:38 94 BPM 80 ms +0.1 % +0.7 % -0.5 %
04:46 94 BPM 66 ms +0.1 % +0.8 % -0.6 %
04:54 94 BPM 79 ms +0.1 % +0.8 % -0.7 %
05:03 96 BPM 123 ms +0.1 % +0.7 % -0.6 %
05:11 94 BPM 115 ms +0.1 % +0.8 % -0.7 %
05:19 96 BPM 117 ms +0.1 % +0.8 % -0.6 %
05:27 94 BPM 56 ms +0.1 % +0.8 % -0.7 %
05:35 94 BPM 75 ms +0.1 % +0.8 % -0.7 %
05:43 94 BPM 68 ms +0.1 % +0.8 % -0.6 %
05:52 94 BPM 67 ms +0.1 % +0.8 % -0.7 %
06:00 94 BPM 61 ms +0.1 % +0.8 % -0.6 %
06:08 94 BPM 62 ms +0.1 % +0.8 % -0.7 %
06:16 94 BPM 60 ms +0.1 % +0.8 % -0.7 %
06:24 94 BPM 61 ms +0.1 % +0.8 % -0.6 %
06:32 91 BPM 62 ms +0.1 % +0.9 % -0.7 %
06:41 94 BPM 43 ms +0.1 % +0.8 % -0.7 %
06:49 91 BPM 86 ms +0.1 % +0.8 % -0.7 %
06:57 94 BPM 65 ms +0.1 % +0.9 % -0.7 %
07:05 94 BPM 93 ms +0.1 % +0.9 % -0.8 %
07:13 96 BPM 49 ms +0.1 % +0.9 % -0.7 %
07:21 96 BPM 46 ms +0.1 % +0.8 % -0.7 %
07:29 96 BPM 78 ms +0.1 % +0.7 % -0.6 %
07:38 96 BPM 70 ms +0.1 % +0.7 % -0.6 %

Long sessions are automatically downsampled for browser review; the published JSON remains the source for the complete web-review series.

METADATA

Session Context

Session ID
TRP-EXP-20261004-133024
Date & Time
Oct 4, 2026 1:30 PM
Subject
S001
Duration
07:43
EEG Sampling Rate
256 Hz

ENVIRONMENT

Recorded Conditions

Temperature C
21
Humidity Percent
40
Lighting
Dark
Position
Seated

CALIBRATION

Connection Reference

Calibration Duration
30 sec
Reference IAF
13.00 Hz
Reference Heart Rate
91 BPM
Motion Threshold
2.5319

Calibration establishes a connection-specific reference for EEG bands, motion, optical physiology and automated state screening. It is separate from the experimental baseline recorded during the session.

COMPARISON

Baseline vs Experiment

TIMELINE

Session Trend

CHANNELS

Regional / Electrode Summary

ChannelBaseline ThetaExperiment ThetaBaseline AlphaExperiment Alpha
TP9 13.376 8.999 3.451 1.904
AF7 13.372 17.703 4.544 5.313
AF8 13.918 14.161 4.647 4.231
TP10 10.869 11.068 2.521 5.040

EVENTS

Session Markers

72
SESSION START SYSTEM session
00:00 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
00:03 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
00:11 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
00:19 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
00:28 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
00:36 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
00:44 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
00:52 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
01:00 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
01:01 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
01:08 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
01:16 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
01:25 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
01:33 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
01:41 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
01:50 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:00 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:08 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
02:11 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
02:15 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
02:15 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:19 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:27 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:35 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:43 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:51 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
02:59 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
03:06 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
03:07 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
03:16 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
03:22 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
03:27 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
03:35 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
03:43 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
03:45 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
03:51 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
03:59 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
04:08 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
04:20 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
04:29 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
04:29 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
04:38 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
04:53 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
05:02 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
05:08 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
05:11 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
05:11 elapsed
AUTO: FOCUSED / ACTIVE PATTERN AUTO state_estimate
05:17 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
05:20 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
05:26 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
05:31 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
05:31 elapsed
AUTO: FOCUSED / ACTIVE PATTERN AUTO state_estimate
05:48 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
05:52 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
05:52 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
06:02 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
06:02 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
06:12 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
06:14 elapsed
AUTO: FOCUSED / ACTIVE PATTERN AUTO state_estimate
06:21 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
06:32 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
06:34 elapsed
AUTO: ALPHA ELEVATION — LOW MOTION AUTO eeg_change
06:34 elapsed
AUTO: FOCUSED / ACTIVE PATTERN AUTO state_estimate
06:52 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
06:53 elapsed
AUTO: BETA ELEVATION — LOW MOTION AUTO eeg_change
07:13 elapsed
AUTO: GAMMA ELEVATION — LOW MOTION AUTO eeg_change
07:13 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
07:21 elapsed
AUTO: HIGH-FREQUENCY ACTIVITY WITH MOVEMENT AUTO artifact
07:21 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
07:29 elapsed
AUTO: MOVEMENT DETECTED AUTO movement
07:38 elapsed
SESSION END SYSTEM session
07:41 elapsed

SUBJECT REPORT

Recorded Experiences

0

No subject-reported experiences were included in the published session summary.

Interpretation note: synchronized timing or statistical association does not by itself establish causation. Review should consider signal quality, movement/artifact, protocol timing, controls and repeatability.